<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-25 22-32-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 52 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19158 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,91 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026/04/25 22.31.50 Total samples: 19158 Equivalent time: 0:15:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,7 dBr MIN: 4,6 dBr AVE: 5,91 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2026/04/25 22.31.49) 22.18 22.20 22.22 22.24 22.26 22.28 22.30 0 2 4 6 Pm [dBr]